Brand Name : Supmeter
Model Number : BST106-M10(FL)
Certification : CE
Place of Origin : China
MOQ : 1pcs
Price : Negotiation
Payment Terms : T/T, Western Union
Supply Ability : 500pcs per month
Delivery Time : 3-10 working day
Packaging Details : 1pcs/box
Power Supply : DC24V
DI : 9
DO : 18
AO : 2
COM/COM1 : RS232
COM2 : RS485
TFT-Touch Filling Controller/Digital Weight Indicator For Liquid/Gas/Powder Ration Fillingweigher
Main Features:
Pictures
Data Display&Quick Setting
Name | Description | Authorization |
[NET] | Net Weight [Weight Unit]. | |
[FIL] | Filling Process Ended. | |
[GROSS] | Gross Weight. | |
[HIGH] | Gross Weight Upper Limit Alarm. | |
[OVLD] | Overload Alarm. | |
[PCS] | Batch Count. | |
[FINAL] | Final Filling Weight. | |
[▲]/[HI] | Positive Deviation Alarm and ‘Deviation & Limit Set’. | Administrator |
[▼]/[LO] | Negative Deviation Alarm and ‘Deviation & Limit Set’. | |
[TOT] | Totalized Weight. | |
[Date&Time] | Date&Time. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[DRUM] | DI switch ‘Empty Drum Ready’ turned on. | |
[UP] | Filling Gun Lift in Place. | |
[DOWN] | Filling Gun Lowered in Place. | |
[HIT] | Filling Gun Impacting Drum Alarm. | |
[ZERO] | Gross Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[FIN] | Target Batch [Count/Weight] Finished. | |
[Highest Filling Position ] | DI switch ‘Highest Step-filling Position Limit’ turned on. | |
[RECIPE] | ‘Working Recipe No.’ Selection. | All Users |
Recipe Parameter Setting. | Engineer | |
[TARGET] | ‘Target Value’ Setting. | All Users |
[HIGH] | ‘SP1 Lead Value for High-speed Filling’ Setting. | Engineer |
‘DO Filling's Mode’ Parameter Setting. | Administrator | |
[MED] | ‘SP2 Lead Value for Medium-speed Filling’ Setting. | Engineer |
‘DO Filling's Mode’ Parameter Setting. | Administrator | |
[FALL] | ‘SP3 Fall Value for Low-speed Filling’ Setting. | Engineer |
‘Fall Value Auto Correction’ Parameter Setting.
| Administrator | |
[MODE] | APP1 Fill on Top / APP2 Fill on Bottom / APP3 Step-fill from Bottom. Refer to Parameter [300] ‘Application Mode’. | |
[BAT. CNT] | ‘Target Batch Count’ Setting. | All Users |
[BAT. WT] | ‘Target Batch Weight’ Setting. | |
[Label Print Information] | Label title, No., Name and Checker Setting. |